DC MCB (≤600Vdc)
DC MCB (≤600Vdc)

DC MCB (≤600Vdc)

DC miniature circuit breaker for PV & energy storage systems

C curve, up to 100A, 300/600VDC, 6kA breaking capacity

1/2/3/4 poles, non-polar wiring

Dual thermal & magnetic protection

DIN rail mount, meets IEC/EN 60947-2

Share:

  • Product Description
  • Specification
  • Product Advantage

Product Description

1. Product Overview

This DC miniature circuit breaker is designed for low-voltage direct current systems, providing overload and short-circuit protection for photovoltaic, energy storage and other DC power distribution circuits. It supports non-polarized wiring and multiple pole configurations, complying with international low-voltage electrical standards.

Specification

2. Core Electrical Ratings

Item

Parameter

Product Type

DC MCB for ≤600 VDC application

Trip Curve

C Curve

Maximum Rated Current (In)

100 A

Rated Operating Voltage

1P: 300 VDC
2P: 600 VDC

Rated Ultimate Short-Circuit Breaking Capacity (Icu)

Up to 6 kA

Instantaneous Trip Current

11 × In (±20% tolerance)

Applicable Poles

1P, 2P, 3P, 4P

Wiring Feature

Non-polarized connection

3. Compliance Standard

Conforms to IEC / EN 60947-2 low-voltage switchgear and controlgear standard.

4. Attached Technical Documents

Product General Catalogue (PDF, 565.91KB)

TUV Type Test Certificate (Rev.01, PDF, 337.69KB)

3D STP Drawings for 1P / 2P / 3P / 4P versions (4.50MB ~ 4.62MB each)

5. Key Design Features

1. Non-polarized terminal connection, no positive/negative polarity restriction during installation

2. Available in 1, 2, 3 and 4 pole modular structures for flexible system matching

3. High DC short-circuit breaking capacity up to 6 kA, reliable fault current interruption

4. C-type thermal-magnetic trip characteristic, suitable for general DC loads including PV combiner boxes and battery cabinets

5. Wide rated current range up to 100 A to meet medium-capacity DC distribution demands

6. Standard DIN rail mounting structure for quick cabinet assembly

6. Application Scenarios

Solar PV DC combiner boxes

Energy storage battery DC distribution systems

Low-voltage industrial DC power supply circuits

Off-grid DC power generation equipment

7. Performance Description

Thermal protection: Disconnect circuit automatically under long-term overload current

Magnetic short-circuit protection: Instant trip at 11×In (±20%) short-circuit current

Optimized DC arc extinguishing structure to suppress DC electric arc during breaking

Modularized single-pole unit design, easy combination of multi-pole specifications on site

Product Advantage

  • 1

    Supports non-polarized wiring for easier field installation

  • 2

    1/2/3/4 pole modular design fits diverse DC system demands

  • 3

    6kA high breaking capacity ensures reliable fault cutting

  • 4

    Dual thermal-magnetic protection guards overload & short circuit

  • 5

    Special arc extinguishing structure adapts to DC circuits

  • 6

    Standard DIN rail mounting for fast cabinet assembly

BackUp

Contact Us

Inquire