SM OS2 MPO MTP TO LC Harness Cable 12 Core
Fiber type: Single-Mode (SM) OS2, 9/125 μm core/cladding, compliant with ITU-T G.652.D/G.657.A1
Configuration: 12-core, MPO/MTP (input) to LC (duplex, UPC/APC polish) connectors, LSZH/PVC jacket
Performance: Operates at 1310/1550 nm; low attenuation (≤0.35/0.20 dB/km), insertion loss (≤0.3 dB/connector), high return loss (≥50/60 dB for UPC/APC)
Mechanical/environmental: -20°C to +60°C operating temp; ≥100 N tensile strength; specified bend radius and crush resistance; ≥500 mating cycles
Key features: High-density, low signal loss, robust build, precise alignment, industry-standard compatibility
Applications: Data centers, LANs/MANs, FTTx, high-speed optical systems, telecom backbones
- Product Description
- Specification
- Product Advantage
Product Description
This specification defines the technical requirements, performance criteria, installation guidelines, and key features of the 12-Core Single-Mode (SM) OS2 MPO/MTP to LC Harness Cable. The cable is designed for high-performance optical signal transmission, facilitating reliable connectivity between MPO/MTP-compatible devices and LC-terminated equipment in optical communication systems.
Specification
2. Core Specifications
2.1 Fiber Type
• Fiber Category: Single-Mode (SM) OS2
• Compliance: Meets ITU-T G.652.D/G.657.A1 standards (compatible with standard single-mode optical systems)
• Core/Cladding Diameter: 9/125 μm (industry-standard dimensions for single-mode transmission)
2.2 Cable Configuration
• Core Count: 12 fibers (arranged in a compact, high-density structure)
• Connector Types:
○ Input Connector: MPO/MTP (male/female, keyed for polarization alignment)
○ Output Connector: LC (UPC or APC polish, duplex configuration)
• Connector Compatibility: MPO/MTP connector compliant with IEC 61754-7; LC connector compliant with IEC 61754-20
• Cable Jacket: Low-smoke zero-halogen (LSZH) or polyvinyl chloride (PVC) (flame-retardant, suitable for indoor use)
• Jacket Color: Standard industry color (e.g., aqua for single-mode, subject to application requirements)
2.3 Transmission Performance
• Operating Wavelength Range: 1310 nm / 1550 nm (standard single-mode operating windows)
• Attenuation:
○ At 1310 nm: ≤ 0.35 dB/km
○ At 1550 nm: ≤ 0.20 dB/km
• Return Loss (UPC Polish): ≥ 50 dB
• Return Loss (APC Polish): ≥ 60 dB
• Insertion Loss: ≤ 0.3 dB per connector (typical value, maximum ≤ 0.5 dB)
• Crosstalk: ≤ -50 dB (at operating wavelengths)
2.4 Mechanical & Environmental Characteristics
• Operating Temperature Range: -20°C to +60°C (for indoor use)
• Storage Temperature Range: -40°C to +85°C
• Tensile Strength: ≥ 100 N (during installation and operation)
• Bend Radius:
○ Static (no tension): ≥ 10 × cable outer diameter
○ Dynamic (under tension): ≥ 20 × cable outer diameter
• Crush Resistance: ≥ 1500 N/100 mm (minimum load without performance degradation)
• Connector Durability: ≥ 500 mating/unmating cycles (maintaining insertion loss ≤ 0.5 dB)
3. Features
• High-Density Connectivity: 12-core design enables space-efficient integration in data centers and optical distribution frames (ODFs).
• Low Insertion Loss & High Return Loss: Ensures minimal signal attenuation and reflection, optimizing transmission quality.
• Stable Mechanical Performance: Robust jacket and connector construction withstands installation stress and environmental variations.
• Precise Connector Alignment: Keyed MPO/MTP and LC connectors ensure accurate polarization and repeatable mating.
• Wide Compatibility: Compliant with industry standards, compatible with most MPO/MTP and LC-based optical equipment.
4. Applications
• Data Center Interconnections (e.g., server-to-switch, switch-to-router links)
• Local Area Networks (LANs) and Metropolitan Area Networks (MANs)
• Optical Distribution Systems (ODSs) and Fiber-to-the-X (FTTx) deployments
• High-Speed Optical Communication Systems (e.g., 10G/40G/100G Ethernet, SDH/SONET)
• Telecommunication Backbone Networks and Enterprise Network Infrastructures
5. Installation Guidelines
• Prior to installation, inspect the cable and connectors for physical damage (e.g., bent fibers, cracked connectors, jacket abrasion).
• Ensure mating connectors are clean and free of dust/debris; use approved optical connector cleaning tools (e.g., lint-free wipes, cleaning sticks) to remove contaminants.
• Align the key of the MPO/MTP connector with the corresponding slot on the mating port to avoid misalignment damage.
• Insert connectors firmly but gently; do not apply excessive force (maximum insertion force ≤ 20 N).
• Maintain the specified bend radius during routing and installation to prevent fiber breakage or performance degradation.
• Avoid exposing the cable to extreme temperatures, moisture, or chemical substances during installation and operation.
• After installation, verify signal transmission performance using an optical power meter or OTDR (Optical Time-Domain Reflectometer) to ensure insertion loss and return loss meet specifications.
6. Assembly Requirements
• Fiber Termination: Fibers are precision-terminated with MPO/MTP and LC connectors using industry-standard assembly processes (e.g., epoxy curing, polishing).
• Polishing Quality: Connector end-faces are polished to UPC/APC standards, with no scratches, pits, or contamination.
• Cable Length: Customizable according to application needs (standard lengths range from 1m to 10m; longer lengths available upon request).
• Labeling: Each cable is labeled with core count, fiber type, and connector types (labeling material is oil-resistant and durable).
• Quality Control: 100% tested for insertion loss, return loss, and continuity before delivery; test reports are available upon request.
Product Advantage
-
1
High-density connectivity: 12-core design saves space for efficient integration in compact environments like data centers.
-
2
Superior transmission quality: Low insertion loss and high return loss minimize signal attenuation and reflection.
-
3
Robust durability: Sturdy jacket and connectors withstand installation stress, environmental changes, and repeated mating (≥500 cycles).
-
4
Precise & reliable alignment: Keyed MPO/MTP and LC connectors ensure accurate polarization and consistent performance.
-
5
Broad compatibility: Compliant with ITU-T/IEC standards, works seamlessly with most MPO/MTP and LC-based optical equipment.
-
6
Versatile applicability: Suitable for high-speed networks, data centers, FTTx, and telecom backbones, meeting diverse transmission needs.